NAO-X Touch Screen Controller
This state-of-the-art HMI device is specifically designed for use in marine environments. Its die cast aluminum enclosure is waterproof and offers excellent thermal transfer capabilities. The product features a high-brightness sunlight-readable, TFT color display with VGA (640x480)resolution and resistive touch-screen. The product is RINA and GL approved.
2 CANBUS, 1 RS232, 1 RS485 and 1 Ethernet communication ports allow a spread interface capability with onboard systems.
There are more than 100 communication protocols implemented including engines, air conditioning, generators, entertainment systems, digital switching systems, and bridge
functionality between different communication protocols. You also get powerful and intuitive programming with the UniOP Designer 6 software. Vector graphic capabilities include the support of multiple layers. Analog gauge objects, data acquisition and trend presentation.
Trend data can be transferred to an host computer using the Ethernet connection.Data log functionality. The system also presents alarms and an archive of alarm historical data which is useful for troubleshooting. Alarm and event information can be printed or transferred to an host computer using the Ethernet connection.
Benefits
- Rapid Touch Response Times.
- Gloved Hand Response.
- Low Cost.
- Four sizes available (5.7” T-13GN-V, 10.4” T-23GN-V, 12.1” T-3GN-V, 15” T-43GN-V).
- Weather and chemical resistant screen including extended temperature range resistance.
- Bright screen.
- Audio Built in.
- Password and Security Protected.
- Data Acquisition and Trend Presentation- Data transfers to a host computer via the Ethernet connection for log functionality, alarms and historical alarm lists.
Other Features
- Up to 2 configurable CANBUS ports (1 RS232, 1 RS232/422/485) 1 10/100Mbit Ethernet port, 1 USB communication port allowing spread interface compatibility with onboard systems.
- More than 100 Communication Protocols Implemented – (Engines, air conditioning, generators, entertainment systems, digital switching systems, etc.) Bridge function ability between different communication protocols with NaviOP onboard monitoring and control software. Powerful and intuitive programming with UniOP designer 6 software.
- Vector Graphic –Capable of including support of multiple layers. Analog gauge objects and 8 level password protection.
| Display |
Type 5.7" (NA03), 8.4" (NA06) TFT |
| Resolution |
VGA 640 X 480 px |
| Active Display Area |
170.9 X 128.2mm (8.4" Diagonal) |
| Colors |
64K |
| Backlight |
CCFL, 50.000 h (note 1) |
| Brightness |
350 (NA03), 400 (NA06) cd/m2 type |
| Dimming |
Yes |
| CPU |
MIPS 200Mhz |
| Memory |
128MB DDRAM |
| User memory |
64MB Internal Flash Disk |
| Touch screen |
Analog resistive |
| Port 1 |
RS-232 |
| Port 2 |
RS-422 |
| Port 3 |
CAN |
| Port 4 |
CAN |
| Port 5 |
Ethernet 10/100 MBit |
| Connectors |
M12, 8 contacts connector (type LUMBERG PG9 RSHL 8/S 5,5) |
| Vector graphics |
Yes |
| Dual driver capability |
Yes |
| Data acquisition and trends |
Yes |
| Recipe memory |
32 KB |
| UniNet network |
Client/Server |
| Alarms |
1024 |
| Event list |
1024 |
| Password |
Yes |
| Hardware RTC |
Yes, with battery back-up |
| Screen saver |
Yes |
| Buzzer |
Yes, audible feedback for touch screen |
| Battery |
Vanadium-Lithium, rechargeable, not user replaceable |
| Power supply |
voltage 18 - 30 VDC |
| Current consumption |
Max 1A at 24 VDC |
| Fuse |
Automatic |
| Weight |
1.9 Kg (approx.) |
| Operating temperature |
-10 to 60 °C |
| Storage temperature |
-30 to +85 °C |
| Operating and storage humidity |
5 – 85 % RH non-condensing |
| Protection class |
IP67 (front panel) IP66 (rear panel) |
| Faceplate |
LxH 234x189 mm |
| Cutout AxB |
221x176 mm |
| Mounting depth |
See figures |
| CE |
Emission EN 61000-6-4 Immunity EN 61000-6-2 for installation in industrial environments |
| RINA |
Type approval certificate for installation in naval environments. RINA Rules for the Classification of Ships
- Part C, Machinery, System and Fire Protection
- Chapter 3, Section 6, Table 1.
|
| GL |
Type approval certificate for installation in naval environments. GERMANISCHER LLOYD Guidelines for the performance of Type Approvals Part 2, Edition 2003 |
Note 1: the lamp lifetime is the typical value for continuous operation at 25ºC.